7100 Series Stainless Steel Tube Flowmeter
Description
7100 Series Stainless Steel Tube Flowmeter
All 316L stainless steel construction with flanged connections makes this meter suitable for low-flow, high-pressure application
DESCRIPTION
Metering Tube | 316L SS |
Internal Components | 316L SS, Hastelloy® C-276 |
Case and Side Cover | Die-cast Aluminum / Powder Coated with Chemfilm base (RoHS Compliant) |
Fitting Material / Type | 316L SS
¼” FNPT, horizontal |
Scale Cover | 304 SS frame Annealed glass window |
O-Ring | EPR, Buna N, Kalrez® |
PERFORMANCE
Flow Capacities | Water 0.6 to 25 GPH (2.4 to 95 LPH) |
||
Air 1 to 120 SCFH (28.3 to 3,400 SLPH) |
|||
Accuracy | ± 5% of full scale flow | ||
Repeatability | 1% | ||
Turndown | 10:1 | ||
Ambient Temperature | -40°F to 125°F (-40°C to 52°C) | ||
Maximum Temperature | O-Ring | Maximum Temperature | |
EPR | 225° F | (107° C) | |
Buna N | 275° F | (135° C) | |
Viton | 350° F | (177° C) | |
Kalrez | 400° F | (204° C) | |
No O-ring | 400° F | (204° C) | |
FNPT Connection Pressure | Valve models — 1,500 psig
Non-valve models — 4,000 psig |
||
Flange Connection Pressure | Temp F | 150# | 300# |
200° | 225 psi | 600 psi | |
300° | 200 psi | 540 psi | |
400° | 180 psi | 515 psi |
OPTIONS
Alarm | Single, Inductive Slot Sensor (See page 61) |
Certified Calibrations | ISA RP 16.6 |
Control Valves | Inlet and outlet |
CRNs | All Canadian provinces (Flange connections are not CRN approved) |
Rear Mounting Bracket | 304 SS |
Scales | Any volumetric unit |
SPECIFICATIONS
Liquid
Order Number | Full Scale Flow Water GPH | Full Scale Flow Water LPH |
02W | .6 | 2.4 |
04W | 1.2 | 4.5 |
06W | 2.8 | 10.5 |
08W | 5.5 | 20 |
10W | 12 | 45 |
12W | 25 | 95 |
Gas
Order Number | Full Scale Flow Air SCFH | Full Scale Flow Air SLPH |
00A* | 1.0 | 28.3 |
01A | 2.5 | 70 |
03A | 5.5 | 155 |
05A | 13 | 360 |
07A | 24 | 680 |
09A | 55 | 1550 |
11A | 120 | 3400 |
* This meter has a titanium float
ALARM OPTIONS:
Inductive Slot Sensor
The alarm mechanism in this flowmeter is an inductive slot sensor. It is a 2-wire, DC, low current device
designed to be used with a switch isolator / barrier.
The operating temperature range for this sensor is -13°F to 158°F (-25°C to 70°C).
Note: We can supply the isolator / barrier upon request, but the user must provide the power supply voltage.
DIMENSIONS (INCHES)
ORDERING:
Use the following guide to determine the specific product number you require.
Example: 7 – 101 – 3 – 2 – 1 – A – 10W – D
710 | |||||||
Meter Series | Fitting Material |
O-Ring Material |
Scale Desired |
Valve Option |
Optional Alarm |
Order Number |
|
316L SS, 1⁄4” FNPT – 1
|
EPR – 1 Buna-N – 2 Viton® – 3 Kalrez® – 4 Without O-ring* – 0 |
Millimeter – 1 GPH—Water – 2 LPH—Water – 3 SCFH—Air—STP – 4 SLPH—Air—STP – 5 Non-standard – 6 |
Inlet 316L SS – 1 Outlet 316L SS – 2 No Valve – 3 Inlet HST C-276 – 4 Outlet HST C-276 – 5 |
No Alarm – 0 With Alarm – A |
See Specifications table |
*The No O-ring option is for non-valve meters only